Instruction Guide – Massa M3 Wireless Sensor Evaluation Kit Page of 14
M3 Kit Guide 111017.docx 10-20-2011
13
PRELIMINARY
APPENDIX C
X4 Gateway Settings for Use with M3 Sensor Software
1) Gateway XBee Configuration (advanced)
a) Extended PAN ID (ID): 1
b) Discovery Timeout (DT): 60
c) Scan Channels (SC): 0x1ffe
d) Peripheral sleep count (SN): 8460
e) Cyclic sleep period (SP): 1000
2) Serial Port Configuration
a) Baud Rate=9600, Data Bits=8, Parity=None, Stop Bits=1, and Flow Control=None
b) Serial Port Services: Access the command line interface (UNCHECK)
3) Python Configuration (Python files)
a) python.zip
b) zigbee.py
c) massa_gateway_appl.py
4) Python Configuration (Auto-start Settings)
a) massa_gateway_appl.py (CHECK Enable)
The Gateway and Sensor in these kits are defaulted to PAN ID = 1 (Personal Area Network) as
indicated in 1a. If another Gateway is in the same vicinity, then both Sensors and Gateway for the
new Gateway and sensor will need to have the PAN ID changed with different value.
M3 Software Configuration Settings
View – Program Settings tab
1) Serial Communications Port: (select proper port USB or null modem cable is plugged into)
2) Discovery Timeout: 12 seconds
M3 Sensor Settings
1) Data Collection Interval: 0
2) Deep Sleep Timer: 0
3) Awake Timer: 31
4) Outgoing Message Mode: 0
Vedere la pagina 13